Switching fuels (dual fuel only), After use each day, Parking brake release (figure 6) – Snorkel XRT33-sn1000-2299CE User Manual
Page 6: Emergency lowering – xrt27, Emergency lowering – xrt33
6
Switching Fuels (Dual Fuel Only)
1. With engine running turn the fuel selector switch
(Figure 1) to the center position.
2. After the engine has quit running select the
appropriate fuel supply.
3. Restart the engine.
After Use Each Day
1. Ensure that the platform is fully lowered.
2. Park the machine on level ground, preferably
under cover, secure against vandals, children or
unauthorized operation.
3. Turn the key switch to OFF and remove the key
to prevent unauthorized operation.
Parking Brake Release (Figure 6)
Perform the following only when the machine will not
operate under its own power and it is necessary to
move the machine or when winching onto a trailer to
transport.
1. Close the needle valve by turning the knob
clockwise.
2. Pump the brake release pump until the parking
brakes release and the wheels can be turned.
3. The machine will now roll when pushed or pulled.
4. Be sure to open the needle valve and verify that
the parking brakes have engaged before the
machine is operated.
Never operate work platform with the parking
brakes released. Serious injury or damage
could result.
Emergency Lowering – XRT27
The emergency lowering control is located at the
rear of the machine at the base of the scissor
assembly, (Figure 4).
1.
Open the emergency lowering valve by pulling
on the knob and holding it on XRT27.
2.
Once the platform is fully lowered, release the
knob to close the valve.
Figure 5: Emergency Lowering Valve Knob
(XRT33)
Figure 6: Parking Brake Release Pump
Needle
Valve
Pump
Figure 4: Emergency Lowering Valve Knob
(XRT27)
Emergency Lowering – XRT33
The emergency lowering control is located in the
control module and is accessible through the fuel
tank access window, (Figure 5).
1.
Hold the control valve in the closed position, then
pump up pressure to release holding valves on
the cylinders.
2.
Once the platform is fully lowered, release the
control valve to close the holding valves.