Class1 106759 - ITL 4LT with 1-wire COM 106296 106299 User Manual
Page 3
Intelli-Tank Manual (106759)071006
– 3 –
Class 1
The Intelli-Tank 4 light tank level is designed to display a liquid’s volume to an
eighth of a tank level accuracy through 180-degree viewable ultra-bright LEDs.
The unit set as a Master uses a 0 – 5 PSI pressure transducer to obtain tank
level information and then relays that information along the data line to units set
as Remotes. Multiple Remote units can be linked to the Master tank level unit.
Tank Level Gauge
C1 – PN
106299 – 12V
106296
–
24V
Pressure Transducer
C1 – PN
102162
Installation Harness
C1 – PN
106690 – Master
106691
–
Remote
User
Manual
C1
–
PN
106759
Modes of Operation:
Master
When the unit is calibrated with a proper pressure signal it
automatically becomes a Master Unit and will send tank level
information along the 1-wire data transfer line to all other Remote
units on the line.
Remote
Units are initially shipped as Remote units. A Remote unit only
requires power, ground and the 1-wire data transfer line. The
Remote unit mimics the Master unit’s display by reading the
appropriate information on the 1-wire data transfer line.
Self Test
When the self test password is entered the unit will perform a self
test and display the results on the display. A Master unit will
command all Remote units to perform the self test also.
Note: All units are shipped as Remote units. A valid calibration will set the unit
as a Master. A Master can be reset as a Remote by entering a password.