Intelli-Tank Manual (106759)071006

– 11 –

Class 1


The calibration process can be cancelled at any time by activating the LEFT

magnetic switch.

1 Point Calibration
1 point calibration only calibrates the full point. The empty calibration is always

set to 0.55V (approximately 1.5 inches of liquid).

1. Make certain that the tank is FULL.
2. Enter the password RLLR LRRL. The unit will respond by flashing the top

LED twice. The unit will then revert to normal operation by displaying

FULL (all LEDs on).


2 Point Calibration

3. Enter the password RLLR LLRL. The unit will respond by flashing the two

center LEDs twice. The unit will then begin cascading the LEDs from top

to bottom (drip).

4. Make certain that the tank is EMPTY and then activate the RIGHT switch

to store that point. The unit will flash the top LED and then turn on all four

LEDs.

5. Fill the tank and then activate the RIGHT switch. The unit will respond by

flashing the top LED then lighting the two center LEDs and then reverting

to normal operation by displaying FULL (all LEDs on).


5 Point Calibration

1. Enter the password RLLR LRLR. The unit will respond by flashing the

two center LEDs five times. The unit will then begin cascading the LEDs

from top to bottom (drip).

2. Make certain that the tank is EMPTY and then activate the RIGHT switch

to store that point. The unit will flash the top LED and then turn on the

bottom LED.

3. Fill the tank to the one-quarter tank point and then activate the RIGHT

switch. The unit will flash the top LED and then turn on the bottom two

LEDs.

4. Fill the tank to the one-half tank point and then activate the RIGHT switch.

The unit will flash the top LED and then turn on the bottom three LEDs.

5. Fill the tank to the three-quarter tank point and then activate the RIGHT

switch. The unit will flash the top LED and then turn on all four LEDs.

6. Fill the tank to the full point and then activate the RIGHT switch. The unit

will respond by flashing the top LED then lighting the two center LEDs and