beautypg.com

Class1 106759 - ITL 4LT with 1-wire COM 106296 106299 User Manual

Page 15

background image

Intelli-Tank Manual (106759)071006

– 15 –

Class 1

Condition

Evaluate

Bottom two LEDs

alternate flashing.
Unit fails self test,

LED 1 flashing.

Check transducer wiring. Ensure +5V at pin A, ground at pin B and

at least .4V at pin C (Signal).

Top two LEDs

alternate flashing.
Unit fails self test,

LED 1 on.

Check transducer wiring. Ensure +5V at pin A, ground at pin B and

no more than 4.8V at pin C (Signal).

Middle two LEDs

alternate flashing.

Perform self test. If it fails with LED 3 on replace unit.

Outer two LEDs

alternate flashing.

Try to recalibrate. If condition remains, check if transducer signal

voltage (pin C) changes as tank level increases. If it doesn’t, replace

transducer. If it does, verify depth of tank. It may be impossible to

calibrate a tank with a depth of less than 6 inches.

Bottom two and

Upper two LEDs

alternate flashing.

The unit is configured as a Remote. If it required to be a Master

then recalibrate. If the unit is required to be a Remote check Data

line (Pin 4) continuity and insure line is not grounded.

No LEDS on.

Check power (Pin 1) and ground (Pin 2) connection.

Master Tank level

display does not

change when actual

tank level is

changing.

Check transducer wiring. Ensure transducer signal voltage (Pin C)

is varying. If it does, check for same signal changes at Pin 6 of tank

level connector (if it is not the same repair wiring). If signal is good

at both locations try re-calibrating.

Remote Tank level

display does not

follow Master

display.

Perform self test. If self test is good, check pin 4 (data line) for

continuity and insure it is not shorted to ground or power. Insure

data line is not routed near noisy power or RF sources.

Unit fails self test,

LED 2 on.

Check pin 4 (data line) for continuity and insure it is not shorted to

ground or power.

No passwords are

accepted.

If the display issues the “wave off” after entering a password, insure

the unit is installed upright. During power-up the display should

cycle on each LED individually starting with the bottom LED.
Check that the left and right magnetic switches are recognized by

activating each switch and verifying that the associated LEDs

illuminate.