beautypg.com

Pinouts, Infinity pinouts – AEM 30-3509 Infinity Plug & Play Harnesses - Honda/Acura OBD2B User Manual

Page 7

background image

1999–2001 Honda B-H-D Series OBD2b

7

© 2014 AEM Performance Electronics

PINOUTS

Infinity Pinouts

Dedicated

Dedicated and not reconfigurable

Assigned

Assigned but reconfigurable

Available

Available for user setup

Not Applicable

Not used in this configuration

Required

Required for proper function

Infinity

Pin

Infinity

Assignment

Honda

Pin

Honda Description

Infinity Hardware

Specification

Notes

1

LS 4

A17

A/C Clutch Relay

Lowside switch, 4A max, No

internal f ly back diode.

See Setup Wizard Page "LowSide
Assignment Tables" f or output assignment
and 2D table "LS4_Duty [%]" f or on/of f
activ ation.

2

LS 5

A19

Engine Speed Pulse

Lowside switch, 4A max with

internal f ly back diode. Inductiv e

load should NOT hav e f ull time

power.

The tachometer is pre-calibrated using a
combination of the LS5_Freq [Hz] 1-axis
table and the LS5_Duty [%] 2-axis table.

3

LS 6

B16*

---

Lowside switch, 4A max with

internal f ly back diode. Inductiv e

load should NOT hav e f ull time

power.

See Wizard page "LowSide Assignment
Tables" f or output assignment.
*Spare injector output Injector 7 f or Inf inity
8h.

4

LS 7

D2*

---

Lowside switch, 4A max, No

internal f ly back diode.

See Wizard page "LowSide Assignment
Tables" f or output assignment.
*Spare injector output Injector 8 f or Inf inity
8h.

5

UEGO1

Heat

---

---

Bosch UEGO controller

Lowside switch f or UEGO heater control.
Connect to pin 4 of Bosch UEGO sensor.
NOTE that pin 3 of the Sensor is heater (+)
and must be power by a f used/switched
12V supply .

6

UEGO1 IA

---

---

Bosch UEGO controller

Trim Current signal. Connect to pin 2 of
Bosch UEGO sensor

7

UEGO1 IP

---

---

Bosch UEGO controller

Pumping Current signal. Connect to pin 6
of Bosch UEGO sensor

8

UEGO1 UN

---

---

Bosch UEGO controller

Nernst Voltage signal. Connect to pin 1 of
Bosch UEGO sensor

9

UEGO1 VM

---

---

Bosch UEGO controller

Virtual Ground signal. Connect to pin 5 of
Bosch UEGO sensor.

10

+12V Perm

Power

B21

Voltage Back Up

Dedicated power management

CPU

Full time battery power. MUST be powered
bef ore the ignition switch input is triggered.

11

Coil 4

Ignition Coil Pulse No. 4

25 mA max source current

0–5V f alling edge f ire. Do NOT connect
directly to coil primary . Must use an ignitor
or CDI that accepts a f alling edge f ire
signal.

12

Coil 3

Ignition Coil Pulse No. 3

25 mA max source current

0–5V f alling edge f ire. Do NOT connect
directly to coil primary . Must use an ignitor
or CDI that accepts a f alling edge f ire
signal.