PHCC Pro Series Pro Series C11 User Manual
Page 15
obstruct this hole or an air lock may prevent the
pump from activating, and the basement will
flood.
MAINTENANCE CHECK LIST
Maintenance should be performed 1-2 times per
year
1. Lift the float switches on both pumps as
described above.
2. Remove all debris from the bottom of the pit.
3. Remove all debris floating in the water.
4. Remove all debris from the float switch cage.
5. Fill the pit with water. Make sure the pumps
turn on at the intended levels.
6. While the pump is running, make sure the
pump is evacuating water at a good pace.
PARTS & SERVICE INFORMATION
You can receive technical support, parts, or
service information by calling Glentronics, Inc.
at 800-991-0466, option #3, or by visiting the
Pro Series website at www.stopflooding.com.