Entering the k factor – J.P. Instruments EDM 960 Twin Pilots Guide User Manual
Page 48

For Your Safe Flight
Page 43
Every time you fine tune the K factor, change it by only half of the
amount calculated above, and record the measurements here:
Date
Engine
EDM
fuel used
actual
fuel used
Curren
t K factor
New
K factor
=
x
/
Pilot’s
initials
IMPORTANT: after adjusting K factors you must apply a correction
factor to the EDM indicated fuel USED and indicated fuel REMaining,
accordingly. We recommend you top the tanks and ‘Refuel’ the EDM to
eliminate this requirement.
Entering the K factor
1. Enter the pilot program mode by simultaneously holding the
STEP
and
LF
buttons for five seconds until you see PROGRAM MODE.
2. Tap the
NEXT
button repeatedly until you see the K factor you wish
to adjust: example: ‘
LFT K-Factor 1 = 29.90’, for left engine.
3. Hold both
NEXT
and Button 2 until you see
ADJUST
. The first digit blinks
(shown here as a larger digit for illustration purposes):
2
9.90
4. Tap the
DIGIT
button to make digit you wish to edit blink: 2
9
.90
5. Tap the
PLUS
or
MINUS
button to change blinking digit: 1
8
.90
6. Repeat items 8 and 9 for the remaining digits.
7. Tap
SAVE
to save and exit the K factor adjustment.
8. Tap
NEXT
repeatedly until you see
END? YES
, then Tap
EXIT
to exit the
program mode.
Note: for any ‘return flow’ transducers, we recommend you do not
attempt to ‘fine-tune’ them, however their K factors do need to be
initially entered into the EDM.