beautypg.com

Manual mode, Scan sequence example – J.P. Instruments EDM 960 Twin Pilots Guide User Manual

Page 23

background image

For Your Safe Flight

Page 18

Manual Mode

To activate Manual Mode, just tap the

STEP

button. Use Manual

mode to lock on one measurement, such as your hottest CHT. Select
desired parameter by tapping

STEP

button. Return to Automatic mode by

tapping

LF

and then tap

STEP

. Disable Automatic mode by setting ‘Auto

Scan Rate 0’. See Pilot Programming.

Scan Sequence Example

Measurement

Example

Comments

EGT, CHT

1340

EGT

1410

376

CHT

421

Square indicates cylinder

TIT, Turbine Inlet
Temperature

1370 TIT 1350

Turbine #1

Shock Cooling

CLD

-22 °/Min -23

Square indicates fastest cooling
cylinder

Difference
between hottest
and coldest EGT

EGT

30 Span 20

Square indicates most widely deviating
cylinder

Compressor
Discharge

Temperature

300 CDT 295

Into intercooler

Carburetor
Temperature

-22 CRB -20

Not available when CDT is installed

Induction Air
Temperature

125 IAT 120

Out of intercooler

Fuel Remaining

Calculated

REM 83.6 GAL

In gallons, liters, pounds or kilograms

Fuel required to
next GPS WPT or
Destination

Total

REQ 25.9 GAL

Present with GPS interface valid signal
and way point

Fuel Reserve at
next GPS WPT or
Destination

Calculated

RES 11.3 GAL

Present with GPS interface valid signal
and way point

Nautical Miles per
Gal

AIRCRAFT

ECON 04.8 MPG

Present with GPS interface and valid
signal or MPK, MPL, MPP

Time to Empty

Calculated

ENDUR 02:25

Hours:minutes remaining at current
fuel burn rate.

Total Fuel Flow

TOTAL

FF 29.5 GPH

Total fuel burn rate

Fuel Flow

Fuel

14.9 GPH 14.6

Individual engine fuel burn rate

Total Fuel Used

Total

USED 76.9 GAL

Since last refueling or trip total.