Manual mode, Scan sequence example – J.P. Instruments EDM 960 Twin Pilots Guide User Manual
Page 23

For Your Safe Flight
Page 18
Manual Mode
To activate Manual Mode, just tap the
STEP
button. Use Manual
mode to lock on one measurement, such as your hottest CHT. Select
desired parameter by tapping
STEP
button. Return to Automatic mode by
tapping
LF
and then tap
STEP
. Disable Automatic mode by setting ‘Auto
Scan Rate 0’. See Pilot Programming.
Scan Sequence Example
Measurement
Example
Comments
EGT, CHT
1340
EGT
1410
376
CHT
421
Square indicates cylinder
TIT, Turbine Inlet
Temperature
1370 TIT 1350
Turbine #1
Shock Cooling
CLD
-22 °/Min -23
Square indicates fastest cooling
cylinder
Difference
between hottest
and coldest EGT
EGT
30 Span 20
Square indicates most widely deviating
cylinder
Compressor
Discharge
Temperature
300 CDT 295
Into intercooler
Carburetor
Temperature
-22 CRB -20
Not available when CDT is installed
Induction Air
Temperature
125 IAT 120
Out of intercooler
Fuel Remaining
Calculated
REM 83.6 GAL
In gallons, liters, pounds or kilograms
Fuel required to
next GPS WPT or
Destination
Total
REQ 25.9 GAL
Present with GPS interface valid signal
and way point
Fuel Reserve at
next GPS WPT or
Destination
Calculated
RES 11.3 GAL
Present with GPS interface valid signal
and way point
Nautical Miles per
Gal
AIRCRAFT
ECON 04.8 MPG
Present with GPS interface and valid
signal or MPK, MPL, MPP
Time to Empty
Calculated
ENDUR 02:25
Hours:minutes remaining at current
fuel burn rate.
Total Fuel Flow
TOTAL
FF 29.5 GPH
Total fuel burn rate
Fuel Flow
Fuel
14.9 GPH 14.6
Individual engine fuel burn rate
Total Fuel Used
Total
USED 76.9 GAL
Since last refueling or trip total.