Adjusting the map – J.P. Instruments EDM 960 Twin Pilots Guide User Manual
Page 45

For Your Safe Flight
Page 40
Date: 05/14/09
01/01/00
⇔
12/31/99
Hold NEXT and button 2 for 5 seconds
until you see ADJUST. Use Month,
Day, Year to adjust. Tap SAVE to
save changes. Tap NEXT to skip to
next item.
END? Yes
END? Yes
Yes exits the pilot program mode.
No reenters pilot program mode.
Adjusting the HP Constant for Rich of Peak Operation
To fine tune the %HP readout, follow this procedure airborne between
5,000 and 8,000 feet MSL.
1. Enter the pilot program mode by simultaneously holding the
STEP
and
LF
buttons for five seconds.
2. Tap
STEP
repeatedly until you see HP Constants. Hold both
NEXT
and Button 2 until you see ROP and LOP appear in status bar. Tap
ROP
.
Now HP Constant 125
should appear. Hold both
NEXT
and
Button 2 until you see ADJUST momentarily. Adjustment range for
the HP Constant is 45 to 180.
3. Set the MP and RPM per your POH to 70 percent power. Let
conditions stabilize.
4. Adjust the HP Constant value
PLUS
or
MINUS
so that the %HP
reading on the display equals ‘
70
%HP
’. Note: this is the percent of
maximum horsepower.
5. Hold both
NEXT
and Button 2 until you see SET.
Adjusting the MAP
This procedure allows you to adjust the MAP to the altimeter setting at a
sea level airport. NOTE: If airport is not at sea level, use the
correction table to derive corrected sea level altimeter setting).
1. Enter the pilot program mode by simultaneously holding the
STEP
and
LF
buttons for five seconds.
2. Tap
NEXT
repeatedly until you see Lft MAP +0.0. Then hold both
the
NEXT
and Button 2 until you see ADJUST momentarily.