L.B. White Pilot User Manual
Page 42

Pr
ob
lem 7
High limit
s
witc
h is
open.
Is f
an loose
or dir
ty?
Ye
s
No
Ye
s
Ye
s
Ye
s
Ye
s
Tighten f
an wheel set
scre
w(s) to motor
shaft.
Blo
w f
an with
compressed air or
clean with soft br
ush.
Are
there restr
ictions
at air inlet or
outlets (such as
unappro
v
ed
ductw
or
k)?
On heaters without
air pro
ving s
witch, is
motor o
v
erheating
and shutting do
wn?
Ha
v
e
y
ou chec
k
ed f
o
r
proper gas type being
used, pressure or f
o
r
liquid propane in line?
Chec
k b
uilding electr
ical
system.
Repair as
necessar
y.
See heater
nameplate f
o
r correct
v
oltage
.
Is
proper v
oltage
being supplied
to motor?
Is heater
reasonab
ly
clean?
Remo
v
e
restr
iction.
No
No
No
No
Giv
e heater a
thorough cleaning
with a soft br
ush or
compressed air
.
DO NO
T USE
W
A
TER
OR ANY LIQ
UID
CLEANING A
GENTS
.
No
Ye
s
Motor is def
ectiv
e
.
Replace
.
Clean motor housing.
Is motor dir
ty?
No
Chec
k f
or proper fuel and pressure on
nameplate of heater
.
Correct as necessar
y.
August 1999
5.1-8
8
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- I-17 Infraconic (28 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 350 Premier Dual Fuel (33 pages)
- 80 Premier (34 pages)
- 170 Dual Fuel (30 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)
- Sentinel Radiant Tube AT150 40' Center Mount (32 pages)