4.3. Next

Switch.

Pressing the NEXT switch while in program mode will cycle through each output, The Output LOAD LED will turn on
for the active output and the digital display will indicate the load selected by displaying L01-L13.

4.4. Priority

Switch.

The PRIORITY switch selects the sequence and shed priority level for the selected output. The digital display will
show the current priority as the switch cycles through from P00 to P08. Loads sequence on in priority from 1 to 8 and
they shed off in priority from 8 to 1. loads set to priority 0 will never shed but they will sequence on and off.

4.5. Active

Switch.

The ACTIVE switch toggles the switch source either ignition or warning master for the selected output.
IGNITION LED:

Output is tied to the Ignition switch.

WRN MASTER LED:

Output is tied to the master switch.

4.6. Mode

Switch.

The MODE switch toggles through the available modes for load management.
RESPONSE LED:

Output in ON only when the Parking Brake is NOT set.

SCENE LED:

Output is ON only when the Parking brake IS set.

BOTH LED:

Output is on regardless of the Parking Brake status.

4.7. User

Switch.

The USER switch adjust the setpoint voltage for output #13 (term 19). Pressing the button increases the 'trip' point in
0.1 volt increments from 10.5 volts to 14.5 volts for a 12 volt system and 21 volts to 29 volts for a 24 volt system. If the
trip point is set to 13.8 volts or above on a 12 volt system or set to 27.6 volts or above on a 24 volt system the output
acts as an overvoltage indicator and will turn on when the selected voltage is reached. If the 'trip' voltage is set below
13.8 volts for a 12 volt system or 27.6 volts for a 24 volt system the output will activate when the voltage drops to the
setpoint.

4.8. Store

Switch.

The STORE switch saves the current configuration for the selected output. The display will indicate that the value has
been saved by showing 3 dashes (---) and then the load number (Lxx) on the digital display.