Figure 23: maximum recommended driveline lengths, Plumbing connections, 4dk pump – Hale 4DK Series User Manual
Page 42: 4dk6 pump, 4dk pump 4dk6 pump
42
Manual p/n: 029-0020-79-0
4DK Series Pumps
❑
Suspension travel and torque wrap-up can
change a marginal driveline into one that is
unacceptable.
Always consider the full movement of the
driveline.
❑
Center your driveline sliders and ensure they
have sufficient travel to allow for the entire
movement of the suspension.
❑
Do not measure driveline angles using a
bubble protractor. Instead, use a digital
inclinometer.
Remember to zero the inclinometer on the
truck frame, not the ground.
❑
Spilt-shaft drivelines inherently have yoke
phasing that can change with every shift.
This is one reason to design the other
aspects of the driveline more conserv-atively
than a "non-split shaft" truck driveline.
Long drivelines can lead to component vibration
or failure. As the driveline approaches half
critical speed, a vibration will occur that can
damage driveline components.
Figure 23: "Maximum Recommended Drive
Lengths," in the next column, lists the maximum
driveline length using a safety factor of 42% of
critical speed. This table is based on a 0.134”
(3.4mm) wall thickness. Although wall thickness
does not have a significant effect on drive shaft
length for this calculation, it does have some
effect.
Extremely short drive lengths between the pump
and the rear axle can also cause problems from
excessive operating angles when the suspension
articulates. Use caution and conservative design
values when utilizing air ride suspension and
short rear drivelines.
More information on fire apparatus drivelines can
be found in Hale OEM Technical Bulletin # 957.
For application assistance and approval, contact
a driveline equipment manufacturer, such as
Spicer/Dana or Merritor.
Shaft
2.0
2.5
3.0
3.5
4.0
4.5
RPM
2400
47
53
58
63
67
71
2600
45
51
55
60
64
68
2800
44
49
53
58
62
65
3000
42
47
52
56
60
63
3200
41
46
50
54
58
61
3400
39
44
48
53
56
69
3600
38
43
47
51
55
58
3800
37
42
46
50
53
56
4000
36
41
45
48
52
55
Figure 23: Maximum Recommended Driveline Lengths
Driveline tube size (diameter) in inches
PLUMBING CONNECTIONS
4DK Pump
The 4DK pump is provided with a 4” Victaulic
suction connection and a 4” Victaulic opposite-
suction-side discharge connection.
An optional 4” Victaulic suction-side discharge
connection is also available.
4DK6 Pump
The 4DK6 pump is provided with a 6” Victaulic
suction connection and a 4” Victaulic opposite-
suction-side discharge connection.
An optional 4” Victaulic suction-side discharge
connection is also available.