beautypg.com

Mechanical adjustments – BEA Eagle 10 User Manual

Page 4

background image

75.5185.04 20070727

Page 4 of 8

5

Mechanical Adjustments

A.

THE WIDTH OF THE SENSING FIELD IS DETERMINED BY THE CHOICE OF THE PLANAR ANTENNA (OPTION)









Wide sensing field:

3-element antenna

Narrow sensing field:

6-element antenna






SENSING FIELDS ACCORDING TO THE TYPE
OF ANTENNA

The sensing fields above correspond to the
following adjustments:

vertical angle of the antenna: 30°
sensitivity: 9
Mounting height: 7’



B.
THE POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL TILT ANGLE OF THE ANTENNA





SENSING FIELDS ACCORDING TO THE
VERTICAL TILT ANGLE OF THE ANTENNA

The sensing fields on the right correspond
to the following adjustments:

wide sensing field antenna
vertical angle of the antenna: 0°, 20°, 45°
sensitivity: 9
Mounting height: 7’


Carefully remove the

protective cover of the antenna
with a screwdriver.

Change the antenna and

replace the protective cover.

Sensing field as close to the door

as possible:

-antenna set at the position of

Sensing field close to the door:


-antenna set at the position of 30°

Sensing field far from the door:


-antenna set at the position of 45°


30º

B

A

45º

C

3-Element
Antenna

6-Element
Antenna

20º

45º

6.4’ 3.2’

0

3.2’ 6.4’

0

3.2’

6.4’

9.6’

6.4’ 3.2’

0

3.2’ 6.4’

0

3.2’

6.4’

9.6’