BEA IS40 User Manual
Is40 / is40p, Quick setup guide
2
Remote Control Parameters
FUNCTION
AFFECTS
INFRARED OR
MICROWAVE
REMOTE
CONTROL
BUTTON
FUNCTION DESCRIPTION
AUTOMATIC LEARN
TIME
INFRARED
0: 30 seconds
1: 1 minute
2: 2 minutes
3: 5 minutes
4: 10 minutes
5: 20 minutes
6: 60 minutes
9:
∞
(Infi nity)
IMMUNITY
INFRARED
1: Low (Normal)
2: Medium (Rain)
3: High (Snow)
PATTERN
INFRARED
FREQUENCY
INFRARED
1: L - L’ Pulse Frequency
2: H - H’ Pulse Frequency
TARGET SIZE
INFRARED
Defi ne the Minimum Size of Target
1
Sensor Wiring
LABEL
POWER (VAC/DC)
ACTIVATION RELAY
PRESENCE RELAY
12-24
12-24
COM
NO
NC
COM
NO
NC
COLOR
RED
BLACK
WHITE
GREEN
YELLOW
WHITE W/BLACK
STRIPE
GREEN W/BLACK
STRIPE
YELLOW W/BLACK
STRIPE
IS40 / IS40P
QUICK SETUP GUIDE
- The IS40 uses Microwave technology
for activation and Active Infrared (IR)
technology for presence detection
- The IS40P uses Active IR technology for
presence detection only and the activation
relay can be triggered by entering or
exiting the IR fi eld
- Microwave Transceiver can be adjusted
30 degrees
- IR Presence area is 10’ x 10’ at 16’ high
- Operate on 12-24 VAC/DC +/- 10%
- Installation Height: 8’ to 16’
- Ceiling or Wall Mount
- Remote Control Accessible
75.5376.01 EN 20080505 (75.5375)
Page 1 of 2
1 Description
2 Wiring / Setup
IS40P
IS40
LED INDICATORS
MICROWAVE ADJUSTMENT SCREW
MICROWAVE TRANSCEIVER
“The Peak Of Detection”
F2
F2
COMBINED ACTIVE INFRARED / MICROWAVE AND ACTIVE INFRARED ONLY SENSOR
1 x 1
1:
2 x 2
2:
3 x 3
3:
4 x 4
4:
1 x 2
5:
2 x 3
6:
3 x 2
7:
6
7
8
9
DOOR
DOOR
DOOR
DOOR
DOOR
DOOR
DOOR
DOOR
DOOR
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9