beautypg.com

Bunn Dual TF User Manual

Page 9

background image

Page 9

TROUBLESHOOTING (cont.)

(B) Control assembly (Electronic)

3. Contactor (Brewers with Recov-
ery booster)

4. Tank heaters

5. Triac assembly (Electronic)

6. Relay (Brewers with Recovery
Booster)

1. (A) Control thermostat (Electro/
mechanical)

(B) Control assembly (Electronic)

2. Triac assembly (Electronic)

3. Lime build-up

CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water conditions.
Excessive mineral build-up on stain-
less steel surfaces can initiate cor-
rosive reactions resulting in serious
leaks.

1. Strainer/flow control (.750 GPM)

Probable Cause

Water from tank is not hot (cont.).

Spitting or unusual steaming from
sprayhead or airvents.

Inconsistent beverage level in server.

Problem

Refer to

Service

- Control assembly

for testing procedure. See page 20
thru 25

Refer to

Service

- Contactor for test-

ing procedures. See page 16

Refer to

Service

- Tank heaters for

testing procedures. See page 35

Refer to

Service

- Triac assembly for

testing procedures. See page 24

Refer to

Service

- Relay for testing

procedures. See page 31

Refer to

Service

- Control thermo-

stat for testing procedures. See page
18

Refer to

Service

- Control assembly

for testing procedures. See page 20
thru 25

Refer to

Service

- Triac assembly for

testing procedures. See page 24

Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.

(A) Direction of flow arrow must be
pointing towards the brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.

Remedy