beautypg.com

Bunn Dual TF User Manual

Page 7

background image

Page 7

Remedy

(A) Direction of flow arrow must be
pointing towards brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.

Refer to

Service

- ON/OFF switch for

testing procedures. See page 28

Refer to

Service -

Start switch for

testing procedures. See page 34

Refer to

Service -

Timer for testing

procedures. See page 36 or 38

Refer to

Service -

Dispense valve for

testing procedures. See page 19

Refer to

Service

- Control assembly

for testing procedures. See pages
20 thru 25

Refer to

Service

- Brew selector

switch for testing procedures. See
page 14

Refer to

Service

- Server sensor for

testing procedures. See page 29

Check plumbing and shut-off valves.

(A) Direction of flow arrow must be
pointing towards brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.

Refer to

Service

- Solenoid valve for

testing procedures. See page 33

TROUBLESHOOTING (cont.)

Brew cycle will not start (cont.)

Automatic refill will not operate

Problem

Probable Cause

3. Water strainer/flow control (.750
GPM)

4. ON/OFF switch

5. Start switch

6. Timer

7. Dispense Valve

8. Control Assembly (Electronic)

9. Brew selector switch

10. Server sensor

1. No water

2. Water strainer/flow control (.750
GPM)

3. Solenoid Valve (Inlet)

27124 062100