beautypg.com

Bunn Dual TF User Manual

Page 10

background image

Page 10

TROUBLESHOOTING (cont.)

Inconsistent beverage level in server.
(cont.)

Consistently high or low beverage
level in server.

Dripping from sprayhead.

Water overflows filter.

Beverage overflows server

2. Improper water pressure

3. Dispense valve

4. Bypass valve

1. Timer adjustment

1. Dispense valve

1. Bypass valve

2. Needle Valve

3. Type of paper filters

4. No sprayhead

1. Beverage left in server

2. Timer adjustment

3. Dispense valve

Check the operating water pressure
to the brewer. It must be between 20
and 90 psi (138 and 620 kPa).

Refer to

Service -

Dispense valve for

testing procedures. See page 19

Refer to

Initial Set-Up

on page 5 step

#7. For test procedure see page 13.

Adjust the timer as required to
achieve the recommended volume
for each brew cycle.

Refer to

Service

- Dispense valve for

testing procedures. See page 19

Refer to

Initial Set -Up

on page 5

step #7. For test procedures see
page 13.

Refer to

Initial Set-Up

on Page 5

step #7.
.
BUNN

®

paper filters should be used

for proper extraction.

Check sprayhead

The brew cycle should be started
only with an empty server under the
funnel.

Adjust the timer as required to
achieve the recommended volume
for each brew cycle. Refer to

Service

- Timer for testing procedures. See
page 36 or 38

Refer to

Service

- Dispense valve for

testing procedures. See page 19

Problem

Probable Cause

Remedy

27124 050800