beautypg.com

Bryant 352MAV User Manual

Page 4

background image

8. If greasy residue is present on blower wheel, remove wheel

from the blower housing and wash it with an appropriate
degreaser. To remove wheel:

a. Mark blower wheel location on shaft before disassembly

to ensure proper reassembly.

b. Loosen setscrew holding blower wheel on motor shaft.

NOTE:

Mark blower mounting arms and blower housing so each

arm is positioned at the same hole location during reassembly.

c. Mark blower wheel orientation and cutoff plate location

to ensure proper reassembly.

d. Remove screws securing cutoff plate and remove cutoff

plate from housing.

e. Remove bolts holding motor mounts to blower housing

and slide motor and mounts out of housing. Disconnect
capacitor and ground wire attached to blower housing
before removing motor.

f. Remove blower wheel from housing.

CAUTION:

The blower wheel should not be dropped or

bent as balance will be affected.

g. Clean wheel per instructions on degreaser cleaner.

9. Reassemble motor and blower wheel by reversing items 8b

through 8f. Ensure wheel is positioned for proper rotation.

10. Reinstall blower assembly in furnace.

11. Reinstall control box, transformer, and door switch assem-

bly on blower shelf.

12. Reinstall condensate trap and tubing if previously removed.

a. Reinstall condensate trap in hole in blower shelf.

b. Connect condensate trap drain tubes. See Fig. 8 or tubing

diagram on main furnace door for proper tube location.

(1.) Connect 1 tube (blue or blue and white striped)

from collector box.

(2.) Connect 1 tube (violet or unmarked) from inducer

housing.

(3.) Connect 1 tube (relief port, green or pink) from

collector box.

NOTE:

Refer to Table 1 for motor speed lead relocation if leads

were not identified before disconnection.

CAUTION:

Heating air speed selection MUST be ad-

justed to provide proper temperature rise as specified on
the rating plate. Failure to adjust the heating speed may
shorten heat exchanger life.

c. Connect field drain to condensate trap.

NOTE:

Ensure tubes are not kinked or pinched, as this will affect

operation.

13. Reconnect wires.

Refer to furnace wiring diagram and connect thermostat leads if
previously disconnected. (See Fig. 15.)

14. Turn on electrical supply. Manually close blower access

door switch. Use a piece of tape to hold switch closed.
Check for proper rotation and speed changes between
heating and cooling by jumpering R-to-W/W1, R-to-
W/W1-and-W2 and then R-to-Y/Y2 on control thermostat
terminals. (See Fig. 11.)

WARNING:

Blower access door switch opens 115-v

power to control. No component operation can occur.
Caution must be taken when manually closing this switch
for service purposes. Failure to follow this warning could
result in personal injury or death.

15. If furnace is operating properly, release blower access door

switch, replace blower access door, and replace main
furnace door.

III.

CLEANING BURNERS

The following items should be performed by a qualified service
technician. If the burners develop an accumulation of light dirt or
dust, they may be cleaned by using the following procedure:

1. Turn off gas and electrical supplies to furnace.

2. Remove main furnace door.

3. Remove burner box cover.

4. Using backup wrench, disconnect gas supply pipe from gas

valve.

CAUTION:

Label all wires prior to disconnection when

servicing controls. Wiring errors can cause improper and
dangerous operation.

5. Remove wires from gas valve. Note location for reassem-

bly.

6. Remove burner box pressure tube from gas valve regulator

fitting.

7. Remove screws that secure manifold to burner box. (See

Fig. 5.)

TABLE 1—SPEED SELECTION

COLOR

SPEED

AS SHIPPED

White

Common

C

OM

Black

High

Cool

Yellow

Med-High

SPARE

Orange†

Med

High-Gas Heat

Blue

Med-Low

Spare/High-Gas Heat

Red

Low*

Low-Gas Heat

* Continuous blower speed.
† Available on 5-speed blowers only.

Fig. 5—Burner Box Assembly

A96304

MANIFOLD
MOUNTING
SCREW

MANIFOLD

GAS VALVE
REGULATOR
FITTING

GAS VALVE

CELL

PANEL

—4—