beautypg.com

Black Box MWU2000-X21 User Manual

Page 77

background image

77

2.048Mbps Wireless Modem

TECHNICAL: 0118 931 2233

Watch Alarms

Alarms for V1.7

LIU Alarms

In the Counters and Tracers menu, type A to display the alarms of the monitored unit

Message:

Input CLK to LIU is 0


Description:
Appears in a unit with V.35/RS-530/X.21 hardware that is configured in

software as an E1/T1 unit.


Correction:
Select the correct LIU type in the LIU parameters menu.


Message:

LOS (all zeros signal)


Description: Indicates an all zeros signal to an E1/T1 or a Fractional E1/T1 LIU. This may

be caused by a cable problem, or because the end equipment is not connected
to the unit.


Correction: Check the cable and/or the connection of the end equipment to the unit.

Message:

AIS


Description: Indicates an all ones signal to an E1/T1 or a Fractional E1/T1 LIU. This may

be caused by a problem in the cable, which connects the end equipment.


Correction:

Check the cable, which connects the end equipment

.




Message:

No

Input

CLK

to

LIU,

Set

End-Equipment

to

source

clock

Description: Appears in V.35/RS-530/X.21 units that are configured as DCE EXTERNAL

CLOCK or as DTE; indicates that the end equipment does not supply a clock
to the LIU.


Correction: Configure the end equipment to supply the clock, and connect it to the

modem..


This manual is related to the following products: