2.048Mbps Wireless Modem

SALES: 0118 965 5100

2. Select a new resolution. You can enter up to 11 characters in hh:mm:ss.ss format. For

example, to display a tracer of 69 minutes, set the Time Tracer resolution to
00:01:00.0.

Note: Each time you define a new resolution; the time tracer graphs are reset.

Reset Counters

In the Counters and Tracers menu, type 8 to view the Reset Counters. The following
information is displayed:

RESET COUNTER: The number of times the system was reset since the last time the Reset
Counter was cleared.

CAUSE OF LAST RESET: The cause of the last reset. Possible causes are:

Normal Error Condition: A “normal” reset following an error burst. A “normal” reset is

defined as a reset that may occur during regular operation and does not necessarily indicate a
problem, unless its’ rate of occurrence is too high.

Loss of Power: A “normal” reset following an interruption in the power supply

Unexpected Internal Error

Unexpected assertion of HW reset line

Unexpected Loss of CPU clock

Unexpected software reset

Unexpected assertion of SW reset line


All the “Unexpected” causes indicate HW problems that must be checked by Black Box
engineer

Clear Reset Counter


In the Counters and Tracers menu, type 9 to clear the Reset Counter.