Troubleshooting

Problem

Cause

Correction

Automatic transfer switch does not

transfer to generator

1. Generator breaker open.

2. Generator voltage not acceptable.

1. Reset generator circuit breaker.

2. Refer to generator manual.

Automatic transfer switch does not

transfer to utility

1. Essential circuit breaker in main

disconnect panel open.

2. Utility voltage not acceptable.

1. Reset essential circuit breaker.

2. Wait for utility voltage to return to

normal.

Generator is still running after switch

transfers to utility power

Engine cool down period.

Engine should stop after 1 minute.

Generator or supervised loads (air

conditioner, etc.) are operating

improperly when generator is supplying

power

1. A-A or B-B contacts not operating

correctly.

2. Too much load on generator.

1. Check A-A or B-B contacts for

proper operation and/or check

control wiring to external load.

2. Decrease load to generator.

Generator is still running after utility

power is restored

1. Minimum engine run time has not

elapsed.

2. Fuse(s) in transfer switch is

defective.

1. Wait five minutes for transfer switch

to retransfer to utility power.

2. Check fuse(s) and replace if

necessary