Bryant 310JAV User Manual

Page 6

background image

CANADA: Part 7 of NSCNGPIC, Venting Systems and Air
Supply for Appliances

Step 4—Duct Systems

US and CANADA: Air Conditioning Contractors Association
(ACCA) Manual D, Sheet Metal and Air Conditioning Con-
tractors National Association (SMACNA), or American Soci-
ety of Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE) 2001 Fundamentals Handbook Chapter 34.

Step 5—Acoustical Lining and Fibrous Glass Duct

US and CANADA: current edition of SMACNA and NFPA
90B as tested by UL Standard 181 for Class I Rigid Air Ducts

Step 6—Gas Piping and Gas Pipe Pressure Testing

US: NFGC; chapters 5, 6, 7, and 12 and National Plumbing
Codes

CANADA: NSCNGPIC Parts 3, 4, 5, A, B, E and H.

Step 7—Electrical Connections

US: National Electrical Code (NEC) ANSI/NFPA 70–2002

CANADA: Canadian Electrical Code CSA C22.1

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

PROCEDURE

Electrostatic discharge can affect electronic components.
Take precautions during furnace installation and servicing to
protect the furnace electronic control. Precautions will pre-
vent electrostatic discharges from personnel and hand tools
which are held during the procedure. These precautions will
help to avoid exposing the control to electrostatic discharge
by putting the furnace, the control, and the person at the same
electrostatic potential.

1. Disconnect all power to the furnace. Multiple disconnects may

be required. DO NOT TOUCH THE CONTROL OR ANY
WIRE CONNECTED TO THE CONTROL PRIOR TO DIS-
CHARGING YOUR BODY’S ELECTROSTATIC CHARGE
TO GROUND.

2. Firmly touch the clean, unpainted, metal surface of the furnace

chassis which is close to the control. Tools held in a person’s
hand during grounding will be satisfactorily discharged.

3. After touching the chassis, you may proceed to service the

control or connecting wires as long as you do nothing to
recharge your body with static electricity (for example; DO

NOT move or shuffle your feet, do not touch ungrounded
objects, etc.).

4. If you touch ungrounded objects (and recharge your body with

static electricity), firmly touch a clean, unpainted metal
surface of the furnace again before touching control or wires.

5. Use this procedure for installed and uninstalled (ungrounded)

furnaces.

6. Before removing a new control from its container, discharge

your body’s electrostatic charge to ground to protect the
control from damage. If the control is to be installed in a
furnace, follow items 1 through 4 before bringing the control
or yourself in contact with the furnace. Put all used and new
controls into containers before touching ungrounded objects.

7. An ESD service kit (available from commercial sources) may

also be used to prevent ESD damage.

LOCATION

Step 1—General

Some assembly and modifications are required when used in any
of the four applications shown in Figure 4.

This furnace must:

be installed so the electrical components are protected from
water.

not be installed directly on any combustible material other than
wood flooring. Refer to Introduction section.

be located close to the chimney/vent and attached to an air
distribution system. Refer to Air Ducts section.

be provided ample space for servicing and cleaning. Always
comply with minimum fire protection clearances shown on the
furnace clearance to combustible label.

Do not install furnace in a corrosive or contaminated atmo-
sphere. Make sure all combustion and circulating air require-
ments are met, in addition to all local codes and ordinances.

Fig. 4—Multipoise Orientations

A02097

THE BLOWER IS LOCATED

TO THE RIGHT OF THE

BURNER SECTION, AND

AIR CONDITIONED AIR IS

DISCHARGED TO THE LEFT.

THE BLOWER IS

LOCATED BELOW THE

BURNER SECTION, AND

CONDITIONED AIR IS

DISCHARGED UPWARD.

THE BLOWER IS

LOCATED ABOVE THE

BURNER SECTION, AND

CONDITIONED AIR IS

DISCHARGED DOWNWARD

THE BLOWER IS

LOCATED TO THE LEFT

OF THE BURNER SECTION,

AND CONDITIONED AIR IS

DISCHARGED TO THE RIGHT.

5