beautypg.com

Siting the appliance, Fig. 3. appliance pipework connections – Bosch 14/19CBI User Manual

Page 6

background image

The appliance may be installed in any room subject to the
requirements of the current IEE regulations and, in Scotland, the
relevant electrical provisions of the Building Regulations with
respect to the installation of appliances in rooms containing
baths or showers.
If the appliance is installed in a room containing a bath or
shower, any switch or appliance control using mains electricity
must NOT be able to be touched by a person using the bath or
shower.
The appliance shall not be installed in a room or internal space
below ground level when it is intended for use with LPG propane
(G31). This does not preclude the installation into a room or
space which are basements with respect to one side of the
building but are open to the ground on the opposite side.
The appliance is NOT suitable for external installation.
The wall must be able to support the weight of the appliance.
Refer to Table 4.
The specified clearances must be available for installation and
servicing. Refer to Table 7 and Fig.2.
The appliance can be installed in a cupboard/compartment to
be used for airing clothes providing that the requirements of
BS6798 and BS5440/2 are followed.
The clearance between the front of the appliance and the
cupboard/compartment door should be not less than 25mm for
air circulation.

4. Siting The Appliance

6

Fig. 2. Appliance casing dimensions and

required clearances.

Side view

260mm

600mm*

30mm*

200mm*

5mm*

* Space required for installation and servicing. Refer to Table 7

Front view

390mm

5mm*

36mm

150mm

600mm

Fig. 3. Appliance pipework connections

Fixing clip

GAS

25mm

36mm

88mm

165mm

FLOW

RETURN

100mm

30mm

(Rear only flue)

Rear only flue

Rear only flue

External

flue turret

142mm