GAS SUPPLY SYSTEM - BASED ON NG (G20)

TOTAL LENGTH OF GAS SUPPLY PIPE (COPPER) metres

3

6

9 12

MAXIMUM GAS DISCHARGERATE - PRESSURE DROP 1mbar. m

3

/h

PIPE DIAMETER mm

8.7

5.8

4.6

3.9

22

18.0

12.0

9.4

8.0

28

Table 6

CLEARANCES (mm)

INSTALLATION

SERVICE

ABOVE APPLIANCE - INTERNAL REAR FLUE

30

30

ABOVE APPLIANCE - EXTERNAL FLUE TURRET 180 180
IN FRONT OF APPLIANCE

600

600

BENEATH APPLIANCE 200

200

RIGHT HAND SIDE 5

5

LEFT HAND SIDE

5 5 *

**

Table 7

SEALED SYSTEM CAPACITY - 10 litre vessel

TOTAL SYSTEM VOLUME

litres

INITIAL

INITIAL CHARGE PRESSURE bar

PRESSURE bar

0.5

1.0 1.5

1.0

72

92

N/A

1.5

39

53 64

Table 8

PERFORMANCE SPECIFICATIONS

PRIMARY WATER CAPACITY 9/14CBi 1.6 litres 14/19 & 19/24CBi 2.1 litres

STATIC HEAD MINIMUM 1.2M MAXIMUM 30M

MAXIMUM FLOW TEMPERATURE

82°C (nom)

MAXIMUM CENTRAL HEATING SYSTEM OPERATING PRESSURE (Sealed System)

2.5 bar

MINIMUM CENTRAL HEATING SYSTEM SET PRESSURE

(Sealed System)

0.12 bar

OUTPUT TO CENTRAL HEATING 9/14CBi 9.0 - 14.0kw 14/19CBi 14.0 - 19.05kw 19/24CBi 19.05 - 23.45kw

NOx CLASSIFICATION FOR CBi APPLIANCES Class 1

SEDBUK NUMBER AND BAND* 9/14CBi NG 78.5 D 14/19CBi NG 79.4 D 19/24CBi NG 78.4 D

9/14CBi LPG 81.0 D 14/19CBi LPG 81.7 D 19/24CBi LPG 80.8 D

Table 5

The appliance can be installed on the above clearance dimensions however, for improved access the following is suggested:
* Improved access - 50mm is recommended
** For improved access minimum clearance when fitted to an adjacent LHS wall is 100mm
NOTE: It is possible to fit the appliance in an unventilated compartment. Refer to Section 6 for details.

MECHANICAL SPECIFICATIONS

FLOW - COPPER TAILS 22mm

RETURN - COPPER TAILS 22mm

GAS INLET 15mm COMPRESSION

CASING HEIGHT 600mm

CASING WIDTH 390mm

CASING DEPTH 260mm

WEIGHT - LIFT 9/14CBi 28kg 14/19 & 19/24CBi 33.5kg

WEIGHT - PACKAGED 9/14CBi 41kg 14/19 & 19/24CBi 47kg

Table 4

GAS SUPPLY SYSTEM - BASED ON PROPANE (G31)

TOTAL LENGTH OF GAS SUPPLY PIPE (COPPER) metres

3

6

9 12 PIPE DIAMETER mm

1.5 — — — 15

8.0

5.2

4.2

3.6

22

15.9

8.8

8.5

7.2

28

* The value is used in the UK Government Standard Assesment Procedure (SAP) for the energy rating of dwellings. The test data from which it has been calculated
have been certified by the GASTEC noified body.