beautypg.com

Technical data – Bosch 14/19CBI User Manual

Page 4

background image

The data plate is fixed to the inner casing cover.

4

3. Technical Data

HYDRAULIC RESISTANCE

BOILER OUTPUT RESISTANCE MIN. FLOW RATE

kW

Metres L/min.

°C

0.06 6.5 20

0.13 11.7 11

14.0 0.28

18.2 11

Table 3 9/14CBi

FLUE DETAILS

HORIZONTAL FLUE

mm

WALL HOLE DIAMETER EXTERNAL FIX

110

INTERNAL FIX

150

MINIMUM LENGTH

425

MAXIMUM LENGTH

725

EXTENDED FLUE MAXIMUM LENGTH

2.5m (19/24CBi) or 3.0m (9/14 and 14/19CBi)

INTERNAL FLUE - REAR ONLY WITHIN CABINET MINIMUM LENGTH

220

MAXIMUM LENGTH

375

FLUE ASSEMBLY DIAMETER

100

VERTICAL FLUE

MINIMUM LENGTH

1100

MAXIMUM LENGTH INCLUDING TERMINAL 3.35m (19/24CBi) or 4.1m (9/14 and 14/19CBi)

Table 2.

FLOW/RETURN

DIFFERENTIAL

NOMINAL BOILER RATINGS (10 Minutes After Lighting)

OUTPUT

INPUT (Net)

GAS RATE

kW

kW

m bar.

m

3

/h

14.00

15.28

11.0

1.62

11.50

12.70

7.3

1.41

9.00

10.11

4.5

1.07

19.05

20.57

11.5

2.18

16.52

17.96

8.5

1.90

14.00

15.38

6.0

1.63

23.45

25.74

12.0

2.72

21.25

23.35

9.8

2.47

19.05

21.16

7.8

2.24

14.00

15.28

27.2

0.63

12.00

13.18

20.4

0.54

10.00

11.17

15.4

0.45

19.05

20.57

25.4

0.84

16.52

17.96

19.0

0.73

14.00

15.38

13.9

0.63

23.45

25.74

29.9

1.05

21.25

23.35

24.6

0.96

19.05

21.16

20.2

0.87

Table 1.

Factory set at maximum input

BURNER

PRESSURE

Natural Gas: Net Input = Gross Input x 0.901
Propane: Net Input = Gross Input x 0.921

NOTE: Pump is fitted externally

9.0

HYDRAULIC RESISTANCE

BOILER OUTPUT RESISTANCE MIN. FLOW RATE

kW

Metres L/min.

°C

0.09 10 20

0.26 18.2 11

19 .05 0.52

24.8 11

Table 3 14/19CBi

FLOW/RETURN

DIFFERENTIAL

14.0

NOTE: FOR VERTICAL FLUE REFER TO A SEPARATE LEAFLET FOR INFORMATION

HYDRAULIC RESISTANCE

BOILER OUTPUT RESISTANCE MIN. FLOW RATE

kW

Metres L/min.

°C

0.15 13.7 20

0.52 24.8 11

23.44 0.73

30.5 11

Table 3 19/24CBi

FLOW/RETURN

DIFFERENTIAL

19.05

9/14CBi NG

14/19CBi NG

19/24CBi NG

9/14CBi LPG

14/19CBi LPG

19/24CBi LPG

APPLIANCE

STANDARD TELESCOPIC FLUE KIT

This manual is related to the following products: