beautypg.com

Built-in kit location, Connection requirements, Checking for gas leaks – Broilmaster BRB-1 User Manual

Page 4: Ocation, Onnections, Afety

background image

Page 4

B101502-1-0311

l

OcatiOn

, c

OnnectiOns

,

anD

s

aFety

Built-In Kit Location

Built-In Kits are designed for outdoor use ONLY.
This Built-In Kit is designed for use with all P3 and T3 Model

Broilmaster

®

gas grills and cannot be used with any other

grill or in any other capacity.
Never install or operate your Built-In Kit in any building,

garage, or other enclosed area.
For your safety, the Built-In Kit should not be installed or

operated under any combustible materials, such as carports,

covered porches, awnings, or overhangs.
Never install or use your Built-In Kit in or on any recreational

vehicle or boat.
CAUTION: THE INSTALLATION AND OPERATION OF

THIS BUILT-IN KIT AT CLEARANCES LESS THAN

SPECIFIED BELOW MAY LEAD TO THE POSSIBILITY OF

FIRE, PROPERTY DAMAGE, OR PERSONAL INJURY.
A minimum clearance of twenty-four (24”) inches is required

from all sides of the island to any combustible material.
Examples of combustible materials are patio furniture,

fences, or the outside of your home.
The area surrounding the built-in kit should be clear to ensure

proper ventilation. Do not obstruct the flow of combustion

and ventilation air in any way. The ventilation openings on

the enclosure must also remain free and clear of debris.
WARNING: DO NOT INSTALL OR OPERATE THIS BUILT-

IN KIT WHERE GASOLINE OR OTHER FLAMMABLE

MATERIALS ARE USED OR STORED. FAILURE TO

COMPLY WITH THIS WARNING COULD RESULT IN

EXPLOSION OR FIRE CAUSING PROPERTY DAMAGE

OR PERSONAL INJURY.

Connection Requirements

CAUTION: NEVER USE LIQUID PROPANE GAS IN A

GRILL DESIGNED FOR NATURAL GAS, OR NATURAL

GAS IN A GRILL DESIGNED FOR LIQUID PROPANE

GAS. QUESTIONS REGARDING DIFFERENT TYPES OF

GASES SHOULD BE DIRECTED TO YOUR LOCAL GAS

COMPANY.
Installation must conform to local codes or, in the absence

of local codes, with the National Fuel Gas Code, ANSI

Z223.1. In Canada, installation shall be in accordance with

CAN/CGA-B149.2 Propane Installation Code, or CAN/

CGA-B149.1 Natural Gas Installation Code, and local

codes where applicable. Consult your local gas company or

Propane gas dealer for code regulations and recommended

procedures.
Broilmaster

®

gas grills and side burners are NOT equipped

with pressure regulators. Your Nat. gas grill operates at a

manifold pressure of seven (7”) inches water column.

CAUTION: THE GRILL AND ITS INDIVIDUAL SHUTOFF

VALVE MUST BE DISCONNECTED FROM THE GAS

SUPPLY PIPING SYSTEM DURING ANY SYSTEM

PRESSURE TESTING AT TEST PRESSURES IN EXCESS

OF 1/2 PSIG.

Checking for Gas Leaks

CAUTION: DO NOT USE AN OPEN FLAME TO CHECK

FOR LEAKS. CHECKING FOR LEAKS WITH AN

OPEN FLAME MAY LEAD TO A FIRE OR EXPLOSION,

RESULTING IN PROPERTY DAMAGE OR PERSONAL

INJURY.
Using the following steps, check for gas leaks during initial

use and each time your Broilmaster

®

gas grill or side burner

is connected to gas or is connected to a cylinder that has

not been used recently
1. Using dish washing detergent and water, make a soapy

solution.

2. Turn OFF the knob on both the grill and side burner’s

control panel.

3. Turn ON the gas at the supply. A hissing sound indicates

a leak. Turn OFF the gas and repair all leaks.

4. If no hissing occurs, apply the soapy solution to all gas

connections.

5. Look for bubbles. Bubbles indicate a leak.
6. If there are bubbles, turn OFF the gas and repair all

leaks.

7. Turn the gas ON and repeat the above procedure until

all leaks are repaired.