Lower the BBA Door Assembly onto the two hinge pins

inside the lower left and right sides of the BBA Frame.

FIGURE 4 .

ENCLOSURE REQUIREMENTS

The enclosure design must be constructed to allow

only storage of the LP cylinder in use thus preventing

storage of a second cylinder. Tank caddy must be

provided for use in the enclosure when employing the

propane self-contained system so as to prevent the

lateral movement of the propane tank cylinder from its

enclosure.
An enclosure for a LP gas cylinder shall be ventilated

by openings at the level of the cylinder valve and at floor

level. The effectiveness of openings(s) for purposes of

ventilation shall be determined with the LP gas supply

cylinder in place. This shall be accompanied by one

of the following: enclosure with one side completely

open; or enclosure having four sides, a top and a

bottom. Refer to the Built-In Kit enclosure construction

guide for proper dimensions of the opening for the

BBA-1 Tank Caddy.
1. At least two ventilation openings at cylinder valve

level shall be provided in the side wall, equally

sized, spaced at 180 degrees (3.14 rad), and

unobstructed. Each opening shall have a total free

area of not less than 1/2 square inch per pound

(7.1 cm

2

/kg) of stored fuel capacity and not

less than a total free area of 10 square inches

(64.5 cm

2

).

2. Ventilation opening(s) shall be provided at floor

level and shall have a total free area of not less

than 1/2 square inch per pound (7.1 cm

2

/kg) of

stored fuel capacity and not less than a total free

area of 10 square inches (64.5 cm

2

). If ventilation

openings at floor level are in a side wall, there

shall be at least two openings. The bottom of the

openings shall be at floor level and the upper edge

no more than 5 inches (127 mm) above the floor.

The openings shall be equally sized, spaced at

180 degrees (3.14 rad) and unobstructed.

3. Every opening shall have minimum dimensions so

as to permit the entrance of an 1/8 inch (3.2 mm)

diameter rod.

The cylinder valve shall be readily accessible for hand

operation. A door on the enclosure to gain access to

the cylinder valves is acceptable, provided it is non-

locking and can be opened without the use of tools.
The enclosure for the LP gas cylinder shall isolate

the cylinder from the burner compartment to provide

shielding from radiation, a flame barrier, and protection

from foreign material, such as hot drippings.
There shall be a minimum clearance of 2 inches

(50.8 mm) between the floor of the LP gas cylinder

enclosure and the ground.
The design of the outdoor cooking gas appliance shall

be such that the LP gas cylinder can be connected,

disconnected and the connections inspected and

tested outside the cylinder enclosure; and those

connections which could be disturbed when installing

the cylinder in the enclosure can be leak tested inside

the enclosure.

BBA T

ANK

C

ADDY

I

NSTALLATION

4

F

IGURE

4

HINGE

PIN