beautypg.com

Sharp UP-600 User Manual

Page 49

background image

48

2. Master declaration

— when the master or back-up master breaks down

When the master or back-up master breaks down, the master declaration procedure should be

performed to inform satellites of the breakdown.

(1) When the master breaks down — Master declaration at the back-up

master

1) A satellite detects a breakdown of the master through the system retry function when it is

sending updated GLU/PBLU data to the master. At this point, the message “NO REPLY/

MASTER” appears in the pop-up window of the display.

NO REPLY/MASTER

* For the system retry function, see pages

57 - 58

.

2) The master declaration operation must be done at the back-up master. This operation

informs the other satellites that the master has broken down and the back-up master will

serve as the master hereafter. (During this process, operations cannot be performed at

satellites.)

3) Each satellite in the IRC system starts sending updated GLU/PBLU data to the back-up

master.

4) The back-up master processes the received data and sends back the processed data to

each satellite.

Flow of a master declaration at the back-up master

1) Detection of a breakdown

3) Updated data

Satellite

(Processing)

4) Processed data

(Transmission stops.)

Master declaration

2) Master
declaration

Back-up master

Master

This manual is related to the following products: