Procedure:

A. Black Level Adjustment: (DLP brightness)

1.

Change pattern of pattern generator :

Pattern : Black (Gray 0)

2.

Adjust DLP Brightness to let the black picture to just distinguish.

B. White Level Adjustment: (AD contrast---R,G,B gain)

1. Change pattern of pattern generator :

pattern : White (100% Gray)

2. Use Lux meter to measure the white level. Adjust the contrast value of AD9883 (RGB)

to let the light output to just max.

3. Change to

32-gray (0 ~ 100%)

pattern. All steps must appear,

C. Offset adjustment at low brightness (AD R, G, B offset)
1. Change Timing and pattern of pattern generator :

pattern : 10% Gray

2. Set user color temp to 6500K.
3. Adjust AD9883 Red and Blue Offset to meet 6500K color spec.

D. Color Temperature at high brightness (Scalar Gamma R, G, B Gain)
1. Change Timing and pattern of pattern generator :

Timing : 800x600@60Hz (H:37.879Khz,V:60.317Hz)

Pattern : 80% gray

2 Color temperature spec: CIE 1976 u’, v’ chromaticity)

Color temperature

5400

°K 6500°K 7500°K

36

48

18

27

'

'

'

+

=

v

u

u

x

0.333 0.312

0.296

36

48

18

12

'

'

'

+

=

v

u

v

y

0.333 0.329

0.316

3

12

2

4

'

+

+

=

y

x

x

u

0.210 0.197

0.190

3

12

2

9

'

+

+

=

y

x

y

v

0.473 0.468

0.459

Deviation:

u’v’=

2

'

2

'

(

v

u

+

<=0.010 <=0.010

<=0.010

Color Temp 4 = color temp is the same as that of 6500K