BenQ DLP PROJECTOR PE8700 User Manual
Page 15
14
3.Definition
3.1 Failure Criteria:
The product is expected to perform to its full potential without loss of function,
performance, critical parametric changes, and other undesirable anomalies, over the
applied boundaries of this specification. The following product failure are not allowed within
the boundaries defined in this specification:
1.Failure including permanent damage, critical parametic changes (optical
performance defined in Appendix A), and latent defects.
2.Failure requiring operator intervention.
3.Failure violating external laws, regulatory agency standards, and government
directives.
4.Failure resulting in a safety, potential safety, issue.
3.2 EUT: Equipment under Test
3.3 Q: Peak Acceleration Response divided by acceleration input peak
4.Test Order
Atmospherics, Dynamic, and Safety test sets require separate units and can be
processed in parallel. EUT testing shall be performed serially within each set.
Set 1 (3 units)
Set 2 (3 units)
Set 3
Dynamics: Atmospherics:
Safety/EMC:
Package Drop
Temperature/Humidity, Operating
EFT
Package Vibration Temperature/Humidity,
Non-operating
ESD
Shock Altitude,
Operating EMI-Radiated
Bench Drop
Aging
EMI-Conducted
EMI-Susceptibility