3.Definition

3.1 Failure Criteria:
The product is expected to perform to its full potential without loss of function,

performance, critical parametric changes, and other undesirable anomalies, over the
applied boundaries of this specification. The following product failure are not allowed within
the boundaries defined in this specification:

1.Failure including permanent damage, critical parametic changes (optical
performance defined in Appendix A), and latent defects.
2.Failure requiring operator intervention.
3.Failure violating external laws, regulatory agency standards, and government
directives.
4.Failure resulting in a safety, potential safety, issue.

3.2 EUT: Equipment under Test
3.3 Q: Peak Acceleration Response divided by acceleration input peak

4.Test Order

Atmospherics, Dynamic, and Safety test sets require separate units and can be

processed in parallel. EUT testing shall be performed serially within each set.

Set 1 (3 units)

Set 2 (3 units)

Set 3

Dynamics: Atmospherics:

Safety/EMC:

Package Drop

Temperature/Humidity, Operating

EFT

Package Vibration Temperature/Humidity,

Non-operating

ESD

Shock Altitude,

Operating EMI-Radiated

Bench Drop

Aging

EMI-Conducted

EMI-Susceptibility