3. DVI-Analog Color Alignment Procedure

Default valve(User menu)

contrast color

Sharpness

Video 17

23

3

S-Video 17

23

1

Comp 17

30

0

Comp-HD 17

30

3

RGBHV 17

30

3

DVI-I 17

30

1

The Gamma(RED ,GREEN,BLUE) is

66

for temperature 0,1,2,3,4.


Equipment:

-

Pattern generator (Chroma 2250)

-

Lux meter ( CL-100)

OSD Default value used for DVI-Analog color alignment

Item Value

Item

Value

USER>Picture>

Factory>HDADJ>RG

Brightness 30

R offset

55

Contrast

17 G

offset

63

Color 30

B offset

62

Tint 15

R Gain

89

Sharpness

1 G

Gain

89

Filter 1

B Gain

89

Color Temp

2

Factory>DLP

Brightness

0

Contrast

49

User>Setup>White

Gamma Red, Green,

66

Gamma Red, Green,

0