beautypg.com

Rs-232c port specifications, Connecting a pc – Pioneer KRL-46V User Manual

Page 43

background image

Connecting a pC

C1 C2 C3 C4 P1 P2 P3 P4

Communication conditions

Set the RS-232C communications settings on the PC

to match the TV’s communications conditions. The

TV’s communications settings are as follows:

Baud rate:

9,600 bps

Data length:

8 bits

parity bit:

None

Stop bit:

1 bit

Flow control:

None

Communication procedure

Send the control commands from the PC via the RS-

232C connector.

The TV operates according to the received command

and sends a response message to the PC.

Do not send multiple commands at the same time.

Wait until the PC receives the OK response before

sending the next command.

Make sure to send “A” with the carriage return and

confirm that “ERR” returns before operating.

Command format

0

0

5

5

1

0

0

3

0

0

0

0

9

0

?

?

?

?

?

O

K

E

R

R

response code format

rS-232C port specifications

pC Control of the tV

When a programme is set, the TV can be controlled

from the PC using the RS-232C terminal. The input

signal (PC/video) can be selected, the volume

can be adjusted and various other adjustments

and settings can be made, enabling automatic

programmed playing.

Use an RS-232C serial control cable (cross type)

(commercially available) for the connections.

note

This operation system should be used by a person who is

accustomed to using PCs.

parameter

Input the parameter values, aligning left, and fill with

blank(s) for the remainder (Be sure that four values are

input for the parameter).

When the input parameter is not within an adjustable

range, “ERR” returns (Refer to “Response code

format”).

When “?” is input for some commands, the present

setting value responds.

After sending the return code (0DH), make sure to

send the line feed (0AH) as well.

Command four-digits: Command. The text of four

characters.

Parameter four-digits: Parameter 0–9, blank, ?

RS-232C serial control cable

(cross type)

Eight ASCII codes eCR

Command four-digits

Parameter four-digits Return code

Normal response

Problem response (communication error or incorrect

command)

Return code (0DH)

Return code (0DH)

KRL46V_GB.indd 41

2008/07/09 14:09:08