Agilent Technologies FS2010 User Manual
Page 19
19
The CYCLE variable is made up of the following signals: TRDY#,
FRAME#, IRDY#, C/BE(3:0), DEVSEL# , and STOP#. This variable has
27 symbols defined that can be used to help make triggering, timing
analysis and pattern filtering easier. The following lists the bit pattern
and the corresponding symbol.
Symbol C/BE(3:0
)
FRAME#
IRDY#
DEVSEL# TRDY#
STOP#
INTACK
0000
0 1 1 1
1
SPECIAL CYCLE
0001
0
1
1
1
1
I/O READ
0010
0
1
1
1
1
I/O WRITE
0011
0
1
1
1
1
RESERVED 0100
0
1
1
1
1
RESERVED1
0101
0
1
1 1
1
MEM RD DWORD
0110
0
1
1
1
1
MEM WRITE
0111
0
1
1
1
1
MEM RD BL
1000
0
1
1
1
1
MEM WR BL
1001
0
1
1
1
1
CONF READ
1010
0
1
1
1
1
CONF WRITE
1011
0
1
1
1
1
SPLIT COMPLETION
1100
0
1
1 1
1
DAC 1101
0
1
1
1
1
MEM RD BLOCK
1110
0
1
1
1
1
MEM WR BLOCK
1111
0
1
1
1
1
IO XACTION
001X
0
1
1
1
1
ADDR CYCLE
XXXX
0
1
1
1
1
DATA XFER
XXXX
X
0
0
0
1
IDLE XXXX
1
1
X
X
X
RETRY XXXX
X
0
0
1
0
DISC NXT ADB
XXXX
X
0
0
0
0
DECODE XXXX
0
1
1
1
1
SINGLE DATA DISCON
XXXX
0
0
1
0
0
TARGET ABORT
XXXX
X
1
1
1
0
TARGET RESPONSE (WAIT)
XXXX
0
0
0 1
1
WAIT XXXX
0
0
1
1
1
The CYCLE variable