Chapter 1 Before Use
1-10
Name of part
Function
Exit Cover
Can remove the mis-fed media around Fuser section.
Interface Connector for
IPS
Connects the cable from the controller unit.
D-Sub Connector 36 pins, 3.3Vdc maximum (large)
Folder Port
Connects the cable from the finishing device (Folder, etc).
12Vdc maximum - Not used in North America
Shut Down
Connects the Shutdown Signal Cable.
KIP 9000 will send a shutdown signal to the controller through this
cable. 12Vdc maximum
Service
For Service personnel only
VGA Port
Connect the cable here, which comes from the controller VGA port
by UL-Listed cable for Touch screen LCD. 5Vdc maximum
USB Port
Connect the cable here, which comes from the controller USB Key
Connector Type B for Touch screen LCD. 5Vdc maximum
Top Rear Cover
Can access the Dehumidify Heater Switch.
Power Outlet for IPS
In case you place a controller unit outside of the KIP 9000, it is
possible to supply AC power from the KIP 9000 to the controller
unit if you connect the power cord to this outlet. (220 - 240V, 3A
maximum)
Connected controller unit must meet UL Standard 60950-1 (UL-
Listed)
NOTE: Specification for Power Cord used in North America
Use the following type of Power Cord for a controller unit.
(1) Rating
minimum 250VAC 7A
(2) Plug Type
IEC60320: C13
(3) Socket Type
IEC60320: C14
(4) Cord
H05VV-F 3G-0.75mm
SVT3x18AWG
(5) UL-Listed
Power Cord
Connect to the wall outlet.
Dehumidify Heater
Switch
Turns on/off the Dehumidify Heater.