DelayBetweenSets=0
MaxImageSize=600
Sets the Maximum Print length of the KIP (in inches)
WireCleanTime=12:00
Value is in military time. A Wire Cleaning will be performed every day on the engine at this defined time,
based on the computer clock.
WireCleanAmount=0
Value is a linear feet total. Once FeetSinceWireClean= counts up to this total, a Wire Cleaning will be
performed, in addition to the time established in WireCleanTime=. Automatic wire cleaning is only
available on certain printer models. Other models should have this feature disabled by changing the
value to 0.
FeetSinceWireClean=166.5468
Value is a counter that keeps track of the number of linear feet printed since the last Wire Cleaning.
Once the WireCleanAmount= is reached, a Wire Cleaning will be performed at the time defined in
WireCleanTime=.
RasterMultiplier=1
This value will be multiplied by the –G value in Request Job Tickets or in the
AddHpglCmd= line, whichever applies. It is used to darken the grayscale level of light HP-RTL data.
KipNumberOfRolls=0
KeyCode=
BackupConfigFile=C:\Program Files\KIP\Unattend\WinUntd.Ini-Bak
SCPFilterDir=C:\SCP\Db
JISTolerance=0
Japanese Image Standard, this is a tolerance that will match non-standard sizes and print them to
Japanese Image Standard sizes.
UseKipFinishResponse=True
ExternalJamReprint=False
WaitASCIIJobs=False
IgnoreKeyCardError=True
KipStatDelay=False
AutoTrimPaper=False