D. An alternative method is to clean with a condenser

brush and vacuum.

NOTE

If the condenser is not kept clean, loss of refrigera-

tion efficiency will result.

4.5 PREVENTATIVE MAINTENANCE

It is recommended that a preventative maintenance sched-

ule be followed to keep the freezer clean and operating

properly. The following steps are suggested as a preven-

tative maintenance guide.

WARNING

High voltage will shock, burn or cause death. Turn off

and lock out main power disconnect before servicing.

Do not operate machine with cabinet panels re-

moved.

The United States Department of Agriculture and the Food

and Drug Administration require that lubricants used in

food zones be certified for this use. Use lubricants only in

accordance with the manufacturer's instructions.

A. Daily Checks

Check for any unusual noise or condition and repair

immediately.

B. Month Checks

WARNING

Moving belts and pulleys can crush and dismember.

Do not operate machine with cabinet panels re-

moved.

1. Check drive belts for wear and tighten belts if

necessary. (Refer to Section 4.3)

2. Check the condenser for dirt. (Refer to Section

4.4)

WARNING

Hazardous Voltage

Disconnect all electric power before servicing. Follow

proper lockout/tagout procedures to ensure the power

cannot be inadvertently energized. Failure to disconnect

power before servicing could result in death or serious

injury.

4.6 EXTENDED STORAGE

Refer to the following steps for winterizing the freezer or for

storing the freezer over any long period of shutdown time.

A. Clean thoroughly with warm detergent all parts that

come in contact with mix. Rinse in clear water and dry

all parts. Do not sanitize.

NOTE

Do not let cleaning solution stand in freezer barrel,

hopper pan, or mix pump during the shutdown pe-

riod.

B. Remove, disassembly, and clean the front door,

auger shaft, and mix pump. Leave disassembled

during the shutdown period.

C. Place plastic auger flights in a plastic bag with a

moist paper towel. This will prevent flights from

becoming brittle if exposed to dry air over an extedned

period of time (over 30 days).

CAUTION

Hearing Protection Required!

This procedure emits a loud noise. Wear proper hearing

protection. Failure to wear proper hearing protection

may result in permanent hearing loss.

D. For water-cooled freezers that are left in unheated

buildings, or buildings subject to freezing, the water

must be shut off and disconnected. Disconnect

fittings at water valve inlet and water outlet lines at

frame. The fittings are located at the rear of the

freezer. Run the compressor for 2 - 3 minutes to open

water valve. Blow out all water, first through water

inlet, then through water outlet lines with air or carbon

dioxide. Also drain water supply line to the freezer.

E. Place the mix pump ON-OFF switch, and the POWER

switch in the OFF position.

F.

Disconnect from the source of input of electrical

supply in the building.

4.7 TROUBLESHOOTING

The Troubleshooting Table lists the common problems

that can occur to the freezer.