3v switching characteristics, Cs5509 – Cirrus Logic CS5509 User Manual
Page 5

CS5509
DS125F3
5
3.3V SWITCHING CHARACTERISTICS
(T
A
= 25 °C; VA+ = 5V ±5%; VD+ = 3.3V ±5%; Input
Levels: Logic 0 = 0V, Logic 1 = VD+; C
L
= 50 pF) (Note 2)
Parameter
Symbol Min
Typ
Max
Unit
Master Clock Frequency
Internal Oscillator
External Clock
XIN
f
clk
30.0
30
32.768
-
53.0
330
kHz
kHz
Master Clock Duty Cycle
40
-
60
%
Rise Times
Any Digital Input
Any Digital Output
t
rise
-
-
-
50
1.0
-
µs
ns
Fall Time
Any Digital Input
Any Digital Output
t
fall
-
-
-
20
1.0
-
µs
ns
Start-Up
Power-On Reset Period
t
res
-
10
-
ms
Oscillator Start-up Time
XTAL = 32.768 kHz (Note 12)
t
osu
-
500
-
ms
Wake-up Period
t
wup
-
1800/f
clk
-
s
Calibration
CONV Pulse Width (CAL = 1)
t
ccw
100
-
-
ns
CONV and CAL High to Start of Calibration
t
scl
-
-
2/f
clk
+200
ns
Start of Calibration to End of Calibration
t
cal
-
3246/f
clk
-
s
Conversion
CONV Pulse Width
t
cpw
100
-
-
ns
CONV High to Start of Conversion
t
scn
-
-
2/f
clk
+200
ns
Set Up Time
BP/UP stable prior to DRDY falling
t
bus
82/f
clk
-
-
s
Hold Time
BP/UP stable after DRDY falls
t
buh
0
-
-
ns
Start of Conversion to End of Conversion
t
con
-
1624/f
clk
-
s