4.1Accuracy Results for Active Energy Load Performance

Figure 7. Active Energy Load Performance vs IEC 62053-22 Class 0,2S Standard

Power Factor

Load Current (A)

Current Dynamic Range (x:1)

Error

PF = 1

100

1

0.04%

10

10

0.03%

1

100

0.04%

0.2

500

0.03%

0.1

1000

0.04%

0.05

2000

0.01%

0.03

3333

0.03%

0.025

4000

0.09%

Lagging PF = 0.5

100

1

-0.02%

10

10

0.07%

1

100

0.11%

0.2

500

0.11%

0.1

1000

0.09%

0.05

2000

0.05%

Leading PF = 0.5

100

1

0.08%

10

10

0.00%

1

100

-0.04%

0.2

500

-0.08%

0.1

1000

-0.14%

0.05

2000

-0.14%

Table 4. Active Energy Load Performance

-0.6

-0.4

-0.2

0

0.2

0.4

0.6

0.01

0.1

1

10

100

P

e

rcent E

rror (%)

Load Current (A)

PF = 1

Lagging PF = 0.5

Leading PF = 0.5

IEC 62053-22 Class 0,2S Spec, PF = 1

IEC 62053-22 Class 0,2S Spec, Lagging PF = 0.5 or Leading PF = 0.8

Note: CS5480, where U

n

= 240

V, I

b(max)

= 2.5

(100

A) at 50

Hz