beautypg.com

An362, 3accuracy results for i, Load current performance – Cirrus Logic AN362 User Manual

Page 6

background image

AN362

6

AN362REV1

3.3Accuracy Results for I

RMS

Load Current Performance

Figure 5. I

RMS

Load Current Performance

Load Current (A)

Current Dynamic

Range (x:1)

I

RMS

Register Value

(10-Second Average)

I

RMS

Error

80

1

0.60011034

0.02%

8

10

0.06009873

0.02%

0.8

100

0.006001252

0.02%

0.16

500

0.001200491

0.04%

0.08

1000

0.000600857

0.14%

Table 3. I

RMS

Load Current Performance

-0.3

-0.2

-0.1

0

0.1

0.2

0.3

0.1

1

10

100

Percen

t Erro

r (

%

)

Load Current (A)

Note: CS5480, where U

n

= 240

V, I

b(max)

= 2

(80

A) at 50

Hz