An362, Accuracy test with current transformer ct, u, 240v and i – Cirrus Logic AN362 User Manual

Page 7: Cs5480, Current

background image

AN362

AN362REV1

7

4. Accuracy Test with Current Transformer CT, U

n

= 240V and I

b(max)

= 2.5(100A) at 50Hz

Taehwatrans TZ76V is used as the current sensor. The CT has the turn's ratio of 2500:1. Use 4Ω as the load
resistor. When the meter is applied with the maximum load current, I

max

= 100A, the secondary output voltage

is (100/2500) × 4 = 0.16 V

RMS

, which is below the maximum I-channel input range when setting the PGA for

current channel 1 (I1) to 10x.

High-pass filter (HPF) is enabled on the voltage channel: V1FLT[1:0] = ‘01’

High-pass filter (HPF) is enabled on the current channel: I1FLT[1:0] = ‘01’

Figure 6. Connection between Current Transformer CT and CS5480

CS5480

IIN 1-

IIN 1+

1KΩ

1KΩ

V+

V-

IIN1-

IIN1+

J1

CT

TZ76V

Current

4Ω

1KΩ

1KΩ

27nF

27nF