3.2Accuracy Results for Reactive Energy Load Performance

Figure 4. Reactive Energy Load Performance vs IEC 62053-23 Class 2 Standard

Power Factor

Load Current (A)

Current Dynamic Range (x:1)

Error

sin

= 1

80

1

0.00%

8

10

0.01%

0.8

100

0.01%

0.16

500

-0.02%

0.08

1000

-0.02%

0.04

2000

-0.01%

0.03

3333

0.00%

0.02

4000

-0.03%

Lagging sin

= 0.5

80

1

0.23%

8

10

0.24%

0.8

100

0.17%

0.16

500

0.21%

0.08

1000

0.16%

0.04

2000

0.22%

Leading sin

= 0.5

80

1

-0.20%

8

10

-0.20%

0.8

100

-0.26%

0.16

500

-0.23%

0.08

1000

-0.25%

0.04

2000

-0.24%

Table 2. Reactive Energy Load Performance

-3

-2

-1

0

1

2

3

0.01

0.1

1

10

100

Pe

rc

e

n

t Err

o

r (

%

)

Load Current (A)

sin

ࢥ = 1

Lagging sin

ࢥ = 0.5

Leading sin

ࢥ = 0.5

Note: CS5480, where U

n

= 240

V, I

b(max)

= 2

(80

A) at 50

Hz

IEC 62053-23 Class 2 Spec, sin

ࢥ = 0.5

IEC 62053-23 Class 2 Spec, sin

ࢥ = 1