3.1Accuracy Results for Active Energy Load Performance

Figure 3. Active Energy Load Performance vs. IEC 62053-22 Class 0,2S Standard

Power Factor

Load Current (A)

Current Dynamic Range (x:1)

Error

PF = 1

80

1

0.04%

8

10

0.04%

0.8

100

0.04%

0.16

500

0.04%

0.08

1000

0.07%

0.04

2000

0.05%

0.03

3333

0.06%

0.02

4000

0.02%

Lagging PF = 0.5

80

1

0.05%

8

10

0.05%

0.8

100

0.04%

0.16

500

0.06%

0.08

1000

0.05%

0.04

2000

0.06%

Leading PF = 0.5

80

1

0.04%

8

10

0.04%

0.8

100

0.05%

0.16

500

0.04%

0.08

1000

0.05%

0.04

2000

0.07%

Table 1. Active Energy Load Performance

-0.6

-0.4

-0.2

0

0.2

0.4

0.6

0.01

0.1

1

10

100

Percent Error (%

)

Load Current (A)

PF = 1

Lagging PF = 0.5

Leading PF = 0.5

Note: CS5480, where U

n

= 240

V, I

b(max)

= 2

(80

A) at 50

Hz

IEC 62053-22 Class 0,2S Spec, Lagging PF = 0.5 or Leading PF = 0.8

IEC 62053-22 Class 0,2S Spec, PF = 1