Cdb5466u – Cirrus Logic CDB5466U User Manual
Page 12

CDB5466U
12
DS676DB1
In the CS5466 Pulse Rate Output Window, the Pulse Count, Frequency, Average Freq and Standard Deviation are
displayed for the three energy-to-pulse outputs.
Count Span: The Count Span entry allows for a time period to be specified for counting the energy pulses output
by the CS5466. The Count Span is a decimal number having a range of 0.18 < Count Span < 167,772, with units of
seconds.
Periods to Average: The Periods to Average entry allows an average to be performed on the pulses counted during
the specified Count Span. The Periods to Average is an integer with a range of 1 < Periods to Average < 10,000.
Reset DUT: When this button is selected, the evaluation software will request the microcontroller to hardware reset
the CS5466. The CS5466 will perform a reset as discussed in the CS5466 data sheet.
Start/Stop: Initially the Stop button is hidden. When the Start button is selected, the evaluation software will instruct
the microcontroller to start counting the energy-to-pulse outputs from the CS5466. At this time the Start button is
disabled and the Stop button will appear. The evaluation software will then collect the Pulse Count over a duration
of time specified (in seconds) by the Count Span. The counted pulses will then be averaged over the specified Pe-
riods to Average entry. The Pulse Count and calculated Frequency, Average Freq and Standard Deviation will be
displayed at the end of the cycle.