Figure 24. recommended analog input buffer, 5 high-pass filter and dc offset calibration, R to – Cirrus Logic CS5381 User Manual
Page 17: Figure 24, Cs5381
DS563F2
17
CS5381
3.5
High-Pass Filter and DC Offset Calibration
The operational amplifiers in the input circuitry driving the CS5381 may generate a small DC offset into the
A/D converter. The CS5381 includes a high-pass filter after the decimator to remove any DC offset which
could result in recording a DC level, possibly yielding “clicks” when switching between devices in a multi-
channel system.
The high-pass filter continuously subtracts a measure of the DC offset from the output of the decimation
filter. If the HPF pin is taken high during normal operation, the current value of the DC offset register is frozen
and this DC offset will continue to be subtracted from the conversion result. This feature makes it possible
to perform a system DC offset calibration by:
1.
Running the CS5381 with the high-pass filter enabled until the filter settles. See the Digital Filter Char-
acteristics for filter settling time.
2.
Disabling the high-pass filter and freezing the stored DC offset.
A system calibration performed in this way will eliminate offsets anywhere in the signal path between the
calibration point and the CS5381.
VQ
+
634
Ω
634
Ω
91
Ω
91
Ω
+
-
-
2700 pF
470 pF
470 pF
COG
COG
10 uF
10 uF
ADC AIN+
ADC AIN-
AIN+
AIN-
COG
100 k
Ω
10 k
Ω
10 k
Ω
100 k
Ω
Figure 24. Recommended Analog Input Buffer