beautypg.com

Characteristics and specifications, Recommended operating conditions, Absolute maximum ratings – Cirrus Logic CS4361 User Manual

Page 5

background image

5

CS4361

Confidential Draft

9/30/11

2. CHARACTERISTICS AND SPECIFICATIONS

RECOMMENDED OPERATING CONDITIONS

AGND = 0 V; all voltages with respect to ground.

ABSOLUTE MAXIMUM RATINGS

AGND = 0 V; all voltages with respect to ground.

WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation

is not guaranteed at these extremes.

Parameters

Symbol Min Nom

Max

Units

DC Power Supply

VA
VL

4.75

1.7

5.0
3.3

5.25
5.25

V
V

Specified Temperature Range

Commercial

T

A

-40

-

+85

C

Parameters

Symbol

Min

Max

Units

DC Power Supply

VA
VL

-0.3
-0.3

6.0

VA

V
V

Input Current, Any Pin Except Supplies

I

in

-

±10

mA

Digital Input Voltage (pin 8, RST)

V

IND

-0.3

VA+0.4

V

Digital Input Voltage (all other digital pins)

V

IND

-0.3

VL+0.4

V

Ambient Operating Temperature (power applied)

T

op

-55

125

°C

Storage Temperature

T

stg

-65

150

°C