Figure 3. control port timing - i²c format – Cirrus Logic CS42528 User Manual
Page 12

12
DS586F2
CS42528
SWITCHING CHARACTERISTICS - CONTROL PORT - I²C™ FORMAT
(T
A
= -10 to +70° C; VA=VARX = 5 V, VD =VLS= 3.3 V; VLC = 1.8 V to 5.25 V; Inputs: Logic 0 = DGND, Logic
1 = VLC, C
L
= 30 pF)
Notes:
17. Data must be held for sufficient time to bridge the transition time, t
fc
, of SCL.
18. The acknowledge delay is based on MCLK and can limit the maximum transaction speed.
19.
for Single-Speed Mode,
for Double-Speed Mode,
for Quad-Speed Mode
Parameter Symbol
Min
Max
Unit
SCL Clock Frequency
f
scl
-
100
kHz
RST Rising Edge to Start
t
irs
500
-
ns
Bus Free Time Between Transmissions
t
buf
4.7
-
µs
Start Condition Hold Time (prior to first clock pulse)
t
hdst
4.0
-
µs
Clock Low time
t
low
4.7
-
µs
Clock High Time
t
high
4.0
-
µs
Setup Time for Repeated Start Condition
t
sust
4.7
-
µs
SDA Hold Time from SCL Falling
(Note 17)
t
hdd
0
-
µs
SDA Setup time to SCL Rising
t
sud
250
-
ns
Rise Time of SCL and SDA
t
rc
-
1
µs
Fall Time SCL and SDA
t
fc
-
300
ns
Setup Time for Stop Condition
t
susp
4.7
-
µs
Acknowledge Delay from SCL Falling
(Note 18)
t
ack
-
(Note 19)
ns
15
256 Fs
---------------------
15
128 Fs
---------------------
15
64 Fs
------------------
t buf
t hdst
t
lo w
t
hdd
t high
t sud
Stop
Start
S D A
S C L
t irs
R S T
t
hdst
t rc
t fc
t sust
t susp
Start
Stop
R ep e ate d
t rd
t fd
t ack
Figure 3. Control Port Timing - I²C Format