Figure 16

Figure 15

clearance from the pipe in order to make a

safe installation. However, building insulation

may be installed around the outside of the Wall

Thimble.

C. Connect a Pipe Adapter and Pipe Section

together then seal connection to rear exhaust

outlet. Attach a Single Tee with Clean out

adapter or a Double Tee with Clean-Out

Adapter, and proceed attaching Pipe Sections

up the wall. Installing a Double Tee with

Cleanout Adapter on the exterior of wall, allows

brushing of the Horizontal Vent run through to

appliance (Figure 14).

D. Attach Wall Strap just above the tee. Wall

Straps must be placed every 8-feet along

an exterior vertical run (Figure 15). If your

exterior vertical run terminates horizontally

before penetrating the roofline, install at least

one Wall Strap on the Pipe Section before 90

Degree Elbow and Horizontal Cap (Figure 16).

Under no circumstances can a Vertical Cap be

installed adjacent to vertical wall. PelletVent

Pro offers fixed and Adjustable Wall Straps

to maintain a 1”-3” clearance, as desired. If

Assemble Pipe Sections in the same manner

described in Step 2 of the general instructions.

E. Seal the exterior section of the Wall

Thimble to the wall with non-hardening

waterproof sealant. As an option, you may

also seal the gap between the pipe and Wall

Thimble with sealant.

5.

If the flue exit is on back of the stove, and

a horizontal through-the-wall installation is

desired (Figure 13):

A. Place the appliance according to

manufacturer’s instructions.

B. Connect the Appliance Adapter and

sufficient Pipe Sections the seal and secure to

back of stove. Horizontal Pipe sections must

penetrate Wall Thimble and extend at least 6”