beautypg.com

DuraVent PelletVent Pro User Manual

Page 11

background image

11

Figure 12

Figure 13

Figure 14

Connect the flexible hose with clamp to the

exterior half of the Wall Thimble. Guide the

flex through the opening in black interior half

of Wall Thimble, gently pull the flex towards

appliance (Figure 12), and if necessary trim

excess flex to required length with snips.

Secure flex to combustion air inlet of the stove

with clamp provided. Only connect metal flex

to the appliance; do not substitute or install

plastic flex. The cover plate comes installed

on the lower left corner of the thimble with

intake guard pointing downward to deflect

rain. If it is desired to rotate thimble and air

inlet to another corner, remove the (2) screws

on the inlet guard and re-attach over air inlet

at new location. Secure black interior half of

the Wall Thimble to the interior wall, and the

unpainted exterior half are to be secured to the

exterior wall on both styles of thimbles (Figure

13). The Wall Thimbles adjust to fit walls from

4”-8” thick. For installation in thicker walls an

extension tube may be field fabricated.

WARNING: Do NOT install any insulation

or other material within the Wall Thimble

itself. Doing so can create a fire hazard.

The Wall Thimble requires the created air