VP-773AMP - The VP-773AMP RS-232 Communication Protocol
65
65
1st
Level
2nd Level
3rd Level
4th Level
Range
Func. Note
Flesh
0:4
443
Black Level
-80:80
450
Gamma Mode Gamma Off
0
460
Gamma 0.4
1
Gamma 0.8
2
Gamma 1.2
3
Gamma 1.6
4
Gamma 2.0
5
Gamma 2.4
6
Gamma 2.8
7
Dither
Mode0: Disable error diffusion
0
470
Mode1: In-frame 8:6 conversion
1
Mode2: Intra-frame 8:6 conversion
2
Mode3: In-frame 10:8 conversion
3
Mode4: Intra-frame 10:8 conversion
4
Mode5: In-frame 12:10 conversion
5
Mode6: Intra-frame 12:10 conversion
6
Auto Adjust
0:1
480
Self-clearing
Enhance H Sharpness
-10:10
510
V Sharpness
-10:10
520
Noise
Reduction
Mosquito NR
0:3
531
unavailable in
progressive scan
Combing NR
0:3
532
Temporal NR
0:3
533
Block NR
0:3
534
unavailable in
progressive scan
Scale
Aspect Ratio
Follow input
0
610
1. Single window
only
2. Customization lost
3. In “Follow Input”,
output must be
bigger than input
Follow Output
1
Best Fit
2
Letterbox
3
Overscan
Off
0
620
5%
1
10%
2
Output
Video Resolution
Native
0
631
1. GET command in
native mode returns
the determined
resolution of the
master connection
2. Special OSD
MENU screen,
follow OSD
instructions
640x480@60
1
640x480@75
2
800x600@50
3
800x600@60
4
800x600@75
5
1024x768@50
6
1024x768@60
7
1024x768@75
8
1280x768@50
9
1280x768@60
10
1280x800@60
11