Kramer Electronics VP-773AMP User Manual
Page 69
![background image](/manuals/465022/69/background.png)
64
VP-773AMP - The VP-773AMP RS-232 Communication Protocol
1st
Level
2nd Level
3rd Level
4th Level
Range
Func. Note
Mic1 Delay
0:40 [ms]
272
Mic2 Delay
0:40 [ms]
273
Power
Amplifier
Off
0
280
Power Level 1
1
Power Level 2
2
Power Level 3
3
Power Level 4
4
SDI
Channeling
Group A
None
0 (read only)
291
Activate CH1
1
Activate CH2
2
Bypass
3
Group B
None
0 (read only)
292
Activate CH1
1
Activate CH2
2
Bypass
3
Group C
None
0 (read only)
293
Activate CH1
1
Activate CH2
2
Bypass
3
Group D
None
0 (read only)
294
Activate CH1
1
Activate CH2
2
Bypass
3
Bypassed Group
Unmute
0
295
Mute
1
Process
Deinterlacing
Method
Line Doubler
0
311
Volatile parameter
unavailable in
progressive scan
Motion Adaptive 1
Sync
Current Field
0
312
Unavailable in
progressive scan.
Older Field
1
Film Mode
Off
0
320
Unavailable in
progressive scan
Follow Input
1
24PsF Mode
2
Diagonal
Correction
0:3
330
Unavailable in
progressive scan.
Unavailable when
deinterlacing sync is
older field
MD Sensitivity
LEVEL1
0
340
Unavailable in
progressive scan
LEVEL2
1
LEVEL3
2
LEVEL4
3
LEVEL5
4
Picture
Brightness
-400:400
410
In the OSD menu
the range appears
as -80:80
Contrast
0.1:1.6
420
Color
0.1:1.6
430
Color
Correction
Blue
0:4
441
Green
0:4
442